Coming from V1? Check out the TLDR Migration Guide. Reading the rest of the documentation is still strongly recommended ;-)
Image datasets are enormously diverse: image dimensionality (2D, 3D), modalities/input channels (RGB image, CT, MRI, microscopy, ...),
image sizes, voxel sizes, class ratio, target structure properties and more change substantially between datasets.
Traditionally, given a new problem, a tailored solution needs to be manually designed and optimized - a process that
is prone to errors, not scalable and where success is overwhelmingly determined by the skill of the experimenter. Even
for experts, this process is anything but simple: there are not only many design choices and data properties that need to
be considered, but they are also tightly interconnected, rendering reliable manual pipeline optimization all but impossible!
nnU-Net is a semantic segmentation method that automatically adapts to a given dataset. It will analyze the provided
training cases and automatically configure a matching U-Net-based segmentation pipeline. No expertise required on your
end! You can simply train the models and use them for your application.
Upon release, nnU-Net was evaluated on 23 datasets belonging to competitions from the biomedical domain. Despite competing
with handcrafted solutions for each respective dataset, nnU-Net's fully automated pipeline scored several first places on
open leaderboards! Since then nnU-Net has stood the test of time: it continues to be used as a baseline and method
development framework (9 out of 10 challenge winners at MICCAI 2020 and 5 out of 7
in MICCAI 2021 built their methods on top of nnU-Net,
we won AMOS2022 with nnU-Net)!
Please cite the following paper when using nnU-Net:
Isensee, F., Jaeger, P. F., Kohl, S. A., Petersen, J., & Maier-Hein, K. H. (2021). nnU-Net: a self-configuring
method for deep learning-based biomedical image segmentation. Nature methods, 18(2), 203-211.
If you are a domain scientist (biologist, radiologist, ...) looking to analyze your own images, nnU-Net provides
an out-of-the-box solution that is all but guaranteed to provide excellent results on your individual dataset. Simply
convert your dataset into the nnU-Net format and enjoy the power of AI - no expertise required!
If you are an AI researcher developing segmentation methods, nnU-Net:
nnU-Net is built for semantic segmentation. It can handle 2D and 3D images with arbitrary
input modalities/channels. It can understand voxel spacings, anisotropies and is robust even when classes are highly
imbalanced.
nnU-Net relies on supervised learning, which means that you need to provide training cases for your application. The number of
required training cases varies heavily depending on the complexity of the segmentation problem. No
one-fits-all number can be provided here! nnU-Net does not require more training cases than other solutions - maybe
even less due to our extensive use of data augmentation.
nnU-Net expects to be able to process entire images at once during preprocessing and postprocessing, so it cannot
handle enormous images. As a reference: we tested images from 40x40x40 pixels all the way up to 1500x1500x1500 in 3D
and 40x40 up to ~30000x30000 in 2D! If your RAM allows it, larger is always possible.
Given a new dataset, nnU-Net will systematically analyze the provided training cases and create a 'dataset fingerprint'.
nnU-Net then creates several U-Net configurations for each dataset:
2d
: a 2D U-Net (for 2D and 3D datasets)3d_fullres
: a 3D U-Net that operates on a high image resolution (for 3D datasets only)3d_lowres
→ 3d_cascade_fullres
: a 3D U-Net cascade where first a 3D U-Net operates on low resolution images andnnU-Net then configures these segmentation pipelines based on a three-step recipe:
Read these:
Additional information:
nnU-Net excels in segmentation problems that need to be solved by training from scratch,
for example: research applications that feature non-standard image modalities and input channels,
challenge datasets from the biomedical domain, majority of 3D segmentation problems, etc . We have yet to find a
dataset for which nnU-Net's working principle fails!
Note: On standard segmentation
problems, such as 2D RGB images in ADE20k and Cityscapes, fine-tuning a foundation model (that was pretrained on a large corpus of
similar images, e.g. Imagenet 22k, JFT-300M) will provide better performance than nnU-Net! That is simply because these
models allow much better initialization. Foundation models are not supported by nnU-Net as
they 1) are not useful for segmentation problems that deviate from the standard setting (see above mentioned
datasets), 2) would typically only support 2D architectures and 3) conflict with our core design principle of carefully adapting
the network topology for each dataset (if the topology is changed one can no longer transfer pretrained weights!)
The core of the old nnU-Net was hacked together in a short time period while participating in the Medical Segmentation
Decathlon challenge in 2018. Consequently, code structure and quality were not the best. Many features
were added later on and didn't quite fit into the nnU-Net design principles. Overall quite messy, really. And annoying to work with.
nnU-Net V2 is a complete overhaul. The "delete everything and start again" kind. So everything is better
(in the author's opinion haha). While the segmentation performance remains the same, a lot of cool stuff has been added.
It is now also much easier to use it as a development framework and to manually fine-tune its configuration to new
datasets. A big driver for the reimplementation was also the emergence of Helmholtz Imaging,
prompting us to extend nnU-Net to more image formats and domains. Take a look here for some highlights.
nnU-Net is developed and maintained by the Applied Computer Vision Lab (ACVL) of Helmholtz Imaging
and the Division of Medical Image Computing at the
German Cancer Research Center (DKFZ).
No Description
Python Text Markdown Shell other
Dear OpenI User
Thank you for your continuous support to the Openl Qizhi Community AI Collaboration Platform. In order to protect your usage rights and ensure network security, we updated the Openl Qizhi Community AI Collaboration Platform Usage Agreement in January 2024. The updated agreement specifies that users are prohibited from using intranet penetration tools. After you click "Agree and continue", you can continue to use our services. Thank you for your cooperation and understanding.